			When PxeBcLoadBootFile() fails, it reports a status code to notify listeners (such as telemetry/SEL logging drivers) about the error. However, the current implementation reports the status code for all error conditions, including benign cases, such as where the caller passes Buffer == NULL with EFI_BUFFER_TOO_SMALL to query the required size. This causes false positive error reports in telemetry systems, as EFI_BUFFER_TOO_SMALL with Buffer == NULL is an expected and normal operation for size queries, not an actual error condition. The PXE-E05 error message is already correctly guarded with the condition "(Status == EFI_BUFFER_TOO_SMALL) && (Buffer != NULL)", but the status code reporting was unconditional. Add a buffer null check before REPORT_STATUS_CODE_WITH_EXTENDED_DATA to ensure status codes are only reported for actual errors: - Report when Status != EFI_BUFFER_TOO_SMALL (all other errors) - Report when Status == EFI_BUFFER_TOO_SMALL AND Buffer != NULL (PXE-E05) - Skip when Status == EFI_BUFFER_TOO_SMALL AND Buffer == NULL (size query) This prevents spurious error logs while maintaining proper error reporting for genuine failures including PXE-E05, PXE-E07, PXE-E09, PXE-E99, and all other error conditions. Signed-off-by: Marc Chen <marc.chen@microsoft.com>